Waferpedia

Zeiss

Sigma HDVP

Metrology & InspectionZeiss Sigma family
Research Quality: 40% complete

The Zeiss Sigma HDVP is a scanning electron microscope (SEM) designed for high-resolution imaging. The Zeiss Sigma HDVP offers acceleration voltage from 0.02 kV to 30 kV and a magnification range of 10x to 1,000,000x. The Zeiss Sigma HDVP's specimen chamber measures 358 mm, and the system includes multiple detectors such as HD AsB, CL, STEM, and SCD.[1]

Sigma HDVP — Inventory photo
Fig. 01Sigma HDVPInventory photo[1]

Power

0.02 kV - 30 kV[1]

Optics

10-1.000.000x[1]

What it is

The Sigma HDVP has an acceleration voltage range from 0.02 kV to 30 kV and a magnification range from 10x to 1,000,000x. The specimen chamber measures 358 mm in diameter.[1][3]

The specimen stage provides five axes of movement: X 30 mm, Y 130 mm, Z 50 mm, tilt from -3° to 70°, and rotation 360°. Detectors include an HD AsB detector, a CL detector, a STEM detector, and an SCD. Pumps comprise a turbomolecular pump, an ion getter pump, and an ultimate high vacuum pump. The system is controlled by a PC with Windows 7, 4 GB RAM, a hard disk drive, and a 19-inch TFT monitor.[1]

How it works

General reference — not yet source-verified

The Sigma HDVP uses a field emission electron gun to generate a focused electron beam that is scanned across the sample surface. The primary beam interacts with the sample, producing secondary electrons, backscattered electrons, and other signals, which are collected by detectors to form an image. The variable pressure mode allows imaging of non-conductive samples by introducing a gas into the chamber to reduce charging effects.

What do the numbers mean?

Power & electrical1

Acceleration voltage
0.02 kV - 30 kV[1]
Accurate?

Vacuum & pumping1

Pumps
Turbomolecular pump, Ion getter pump, Ultimate high vacuum pump[1]
Accurate?

Optics & imaging8

Magnification range
10-1.000.000x[1]
Accurate?
Lens control[1]
Accurate?
Chamber detector[1]
Accurate?
In-lens detector[1]
Accurate?
Detector:[1]
Accurate?
HD AsB Detector[1]
Accurate?
Magnification range
10x - 1,000,000x[1]
Accurate?
Detectors
HD AsB, CL, STEM, SCD[1]
Accurate?

Control & software4

Dual joystick control box[1]
Accurate?
Control PC
TFT Monitor 19", Windows 7, 4 GB RAM, HDD[1]
Accurate?
Operating system
Windows 7[1]
Accurate?
User interface
Keyboard, Mouse[1]
Accurate?

Configuration & options15

Electron source[1]
Accurate?
Focus[1]
Accurate?
Stigmator[1]
Accurate?
Beam shift[1]
Accurate?
Specimen chamber
358 mm[1]
Accurate?
Specimen stage movements:[1]
Accurate?
5- Axes:[1]
Accurate?
X: 30 mm[1]
Accurate?
Y: 130 mm[1]
Accurate?
Z: 50 mm[1]
Accurate?
T: -3°-70°[1]
Accurate?
R: 360°[1]
Accurate?
Stage axes
5 axes (X:30 mm, Y:130 mm, Z:50 mm, T:-3°-70°, R:360°)[1]
Accurate?
Display
TFT Monitor, 19“[1]
Accurate?
RAM
4 GB[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What replaced it?

Alternatives

Tools documented as functional equivalents — same process step and wafer size, from a different manufacturer. Each equivalence cites its source.

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Acceleration voltage0.02 kV - 30 kV[1]
  • PumpsTurbomolecular pump, Ion getter pump, Ultimate high vacuum pump[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Not publicly documented

The following facts about the Sigma HDVP are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Sigma HDVP are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Sigma HDVP are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Sigma HDVP are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Sigma HDVP are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Sigma HDVP is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]Equipment inventory listing
  3. [3]Zeiss Axioscope 7 vs Zeiss Sigma HDVP | Waferpedia — waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 5, 2026.

Compare with similar tools

View all →