The Leica TCS SP5 is a spectral confocal and multiphoton microscope system from Leica Microsystems. The Leica TCS SP5 is based on the SP spectral detection module, which allows selection of any spectral emission band in the visible range. The Leica TCS SP5 supports up to five confocal channels simultaneously.[1][2]

LeicaSP5
No photo available yet
  • Plate 012-1 Intro to the Leica SP 5

    Paul Siri WilsonWatch on YouTube
  • Plate 022-1 Intro to the Leica SP 5

    bizmonkey007Watch on YouTube
  • Plate 032-5 Your First Use of the Leica SP 5.mp4 (w/ Commentary)

    bizmonkey007Watch on YouTube
  • Plate 04Part 1: Leica SP5 Training for SP8 Users

    NUBiological Imaging FacilityWatch on YouTube
  • Plate 05Leica DMI 6000 CS Inverted Microscope Confocal SP5 DMI6000 B Predecessor to DMi8 [BOSTONIND] - 6981

    WWW.BOSTONIND.COM | Laboratory & Scientific Lab Equipment | Boston Industries, Inc.Watch on YouTube

What it is

The Leica SP5 is a laser point-scan confocal microscope used for imaging and inspection work in a microscopy core environment. The Leica SP5 is a point-scan confocal microscope with laser lines at 405, 458, 476, 488, 496, 514, 543, 594, and 633nm, and it supports regular and high-speed resonance scanning modes.[4]

The Leica TCS SP5 is a spectral confocal and multiphoton microscope system. The system is a laser scanning microscope platform intended for confocal imaging and multiphoton imaging.[1]

How it works

The Leica TCS SP5 uses spectral detection with selectable emission bands. The SP detection module allows selection of any spectral emission band in the visible range, five spectral bands can be selected simultaneously, and two of the detectors can operate for fluorescence lifetime imaging microscopy.[1]

Where it fits in the process flow

General reference — not yet source-verified

The Leica SP5 sits at the imaging and metrology stage of a laboratory workflow after a sample has been prepared and mounted. The instrument is used to observe fluorescent or otherwise optically active specimens before image analysis or downstream interpretation.

Applications

The Leica SP5 is used for confocal fluorescence imaging in biological research. The instrument is also used for multiphoton imaging, spectral imaging, and fluorescence lifetime imaging microscopy.[1][4]

  • inverted confocal microscopy

What do the numbers mean?

Optics & imaging3

FLIM operation
Two detectors may operate as a sensor for fluorescence lifetime imaging microscopy (SP-FLIM combination)[1]
Accurate?
Detectors
High dynamic sensors with low dark current PMTs[2]
Accurate?
Laser lines
405, 458, 476, 488, 496, 514, 543, 594, and 633 nm[4]
Accurate?

Performance1

Tandem Scanner
Conventional and resonant scanner in one system; switch by computer controlled super precision mechanical actuator[2]
Accurate?

Control & software1

Software
Leica Application Suite Advanced Fluorescence (LAS AF)[5]
Accurate?

Configuration & options10

Manual title
Leica SP5 Inverted Confocal Manual[3]
Accurate?
System type
Spectral confocal and multiphoton microscope system[1]
Accurate?
Detection module
SP spectral detection module[1]
Accurate?
Spectral band selection
Any spectral emission band in the visible range; five spectral bands can be selected simultaneously[1]
Accurate?
Confocal channels
Up to five confocal channels simultaneously[2]
Accurate?
Spectrometer
High efficiency prism spectrometer with loss-free band selection[2]
Accurate?
Conventional scanner features
True confocal point-scanning; extra large field of view (21 mm); 64 Megapixel images (8k x 8k); beam park data acquisition; spot-bleaching FRAP; zoom and pan function; slow scan mode[2]
Accurate?
Resonant scanner features
True confocal point-scanning; large field of view (15 mm); zoom and pan function; 16,000 lines per second; 250 frames per second; 25 frames per second 512 x 512; up to five confocal channels simultaneously[2]
Accurate?
Emission channels
Customizable to 4 channels at Boston University Cellular Imaging Core[4]
Accurate?
Microscope stands
Inverted stand DMI 4000/6000 CS and upright stand DM 5000/6000 CS[5]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What scanning modes does the Leica SP5 support?

The Leica SP5 supports regular and high-speed resonance scanning modes.[4]

Not publicly documented

The following facts about the SP5 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the SP5 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the SP5 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the SP5 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the SP5 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the SP5 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (5)Every fact above is drawn from these public sources
  1. [1]doi.org — doi.orgdoi.org
  2. [2]biology.uiowa.edu — biology.uiowa.edubiology.uiowa.edu
  3. [3]microscopy.duke.edu — microscopy.duke.edumicroscopy.duke.edu
  4. [4]bumc.bu.edu — bumc.bu.edubumc.bu.edu
  5. [5]research.uky.eduresearch.uky.edu
Was this page accurate?

Last updated Oct 4, 2026.

Compare with similar tools

View all →