Produced 1990–Edwards iH 1000 Dry family
Research Quality: 30% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

EdwardsiH 1000 Dry
No photo available yet

Produced

1990–

Power

3 Phase, 208V, 50/60Hz[3]

Vacuum

Dry pump[3]

What it is

The iH 1000 is a five-stage base pump with an innovative cantilever rotor, claw and roots design, which improves dust handling and reduces exhaust noise (Source 2).[4]

The pump is fitted with a single stage mechanical booster pump and totally enclosed water cooled motors (Source 2).[4]

How it works

The absence of oil in the pumping chamber prevents back-migration of hydrocarbons into the evacuated system, providing a clean vacuum environment (Source 2).[4]

The pump includes a gas system that introduces purge gas into the base pump; this purge can be used in an economiser mode on light or medium duty processes to reduce nitrogen consumption (Source 2).[4]

Operation of the iH 1000 can be controlled via a Pump Display Terminal, a process tool interface, an iM Communications Module, or an iH Single Equipment Monitor (Source 2).[4]

Where it fits in the process flow

The iH 1000 operates at pressures between atmospheric and ultimate vacuum, making it suitable for processes that require clean vacuum without oil contamination (Source 2).[4]

Applications

The Edwards iH 1000 dry pump is used for harsh duty processes where particulate, condensable, or corrosive by-products are present (Source 2).[4]

The pump is also applied in load lock, transfer, metrology, lithography, PVD process, PVD pre-clean, RTA, strip/ashing, oxide etch, silicon etch, metal etch, implant source, HPD CVD, RTP, SACVD, MOCVD, and ALD (Source 3).[3]

What do the numbers mean?

Power & electrical4

Motor
3 Phase, 208V, 50/60Hz[3]
Accurate?
Voltage / frequency
200-208 V, 50/60 Hz[4]
Accurate?
Power input
3.5 kW[4]
Accurate?
Rated motor power
5.1 kW[4]
Accurate?

Vacuum & pumping5

Product type
Dry pump[3]
Accurate?
Pumping speed
560 cfm[4]
Accurate?
Ultimate pressure
1.5x10-3 Torr[4]
Accurate?
Pumping speed
589 CFM (60Hz)[3]
Accurate?
Ultimate pressure
7.5 x 10-4 Torr[3]
Accurate?

Dimensions & facilities3

Weight
948 lbs[3]
Accurate?
Weight
430 kg[4]
Accurate?
Dimensions
909 x 839 x 390 mm[3]
Accurate?

Configuration & options7

Manufacturer
Edwards[2]
Accurate?
Model
iH 1000[2]
Accurate?
Inlet connection
ISO 100[4]
Accurate?
Outlet connection
KF 40[4]
Accurate?
Outlet connection
NW 40[4]
Accurate?
Oil capacity
1.48 l[4]
Accurate?
Oil capacity
1.43 liters[3]
Accurate?

Vintage & configurations

  1. 1990Production start[1]

    The iH1000 has been manufactured since the late 1990s.

Documented models & variants

DesignationGenerationVintageChangesSource
iH1000——Base designation listed with vintage-specific part numbers.trilliumus.com[1]
iH1000 Enhanced——Listed as a vintage variant.trilliumus.com[1]
iH1000 HEAC——Listed as a vintage variant.trilliumus.com[1]
iH1000 New Look——Listed as a vintage variant.trilliumus.com[1]
iH1000 Mark V——Listed as a vintage variant.trilliumus.com[1]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Product typeDry pump[3]
  • Pumping speed560 cfm[4]
  • Ultimate pressure1.5x10-3 Torr[4]
  • Pumping speed589 CFM (60Hz)[3]
  • Ultimate pressure7.5 x 10-4 Torr[3]
  • Motor3 Phase, 208V, 50/60Hz[3]
  • Voltage / frequency200-208 V, 50/60 Hz[4]
  • Power input3.5 kW[4]
  • Rated motor power5.1 kW[4]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What are the inlet and outlet connections?

The inlet connection is ISO 100 and the outlet connection is KF 40 (Source 2).[4]

Which applications is the iH 1000 suitable for?

The pump is suitable for PECVD, LPCVD, load lock, transfer, metrology, lithography, PVD process, PVD pre-clean, RTA, strip/ashing, oxide etch, silicon etch, metal etch, implant source, HPD CVD, RTP, SACVD, MOCVD, and ALD (Sources 2 & 3).[4][3]

Not publicly documented

The following facts about the iH 1000 Dry are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • The control-system platform and OS era of the iH 1000 Dry are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the iH 1000 Dry are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the iH 1000 Dry is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the iH 1000 Dry are on record.

    Answerable by: an OEM parts catalog or a service engineer

  • No publicly hosted manuals, SOPs, or datasheets for the iH 1000 Dry are on record.

    Answerable by: university cleanroom staff or an OEM application specialist

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]trilliumus.com — trilliumus.comtrilliumus.com
  2. [2]Equipment inventory listing
  3. [3]provac.com — provac.comprovac.com
  4. [4]ajvs.com — ajvs.comajvs.com
Was this page accurate?

Last updated Sep 24, 2026.

Compare with similar tools

View all →