Waferpedia

Signatone

CM 210

Test & ProbeSignatone CM 210 family
Research Quality: 40% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Signatone CM-210 is a 200mm high precision manual probe system. The CM-210 supports DC, CV/IV, pulsed-IV measurements, high power applications up to 12kV/600A, and RF applications up to 110GHz with 2 and 4 port setups.[1]

SignatoneCM 210
No photo available yet

Power

-200V to +200V DC[1]

Performance

< 1 μm (0.04 mils) by Manual Control[1]

What it is

General reference — not yet source-verified

The Signatone CM 210 is a manual probe station, belonging to the class of analytical test equipment used in semiconductor development and failure analysis. Probe stations allow electrical contact to be made to devices on a semiconductor wafer so that their DC, RF, or high-power characteristics can be measured.

How it works

The CM 210 positions a wafer on a 203 mm diameter chuck that can be moved in X, Y, and Z axes, and rotated in theta. The chuck XY stage provides 205 mm by 205 mm manual travel, with standard resolution of 14 μm and fine resolution of 1.5 μm per degree of knob rotation. The chuck Z stage is pneumatic, with 2.5 mm travel and a repeatability of ±1.0 μm.[1][2]

Microprobes are mounted on a platen above the chuck; the platen is made of nickel-plated steel or optional aluminum. The platen offers a continuous variable lift (CVL) of 0 to 3.175 mm, a fine lift adjustment of 38.1 mm, and a quick lift of 3.175 mm. Up to 10 DC/HV micropositioners, or a mix of RF and DC positioners, can be mounted magnetically or by bolt-down on the platen.[1][2]

The system has an ultra-stable 50 mm thick aluminum base. Contact repeatability by manual control is less than 1 μm. Optional accessories include an active vibration isolation table, a hot chuck system for temperature up to 300 °C, and a motorized or semi-automatic upgrade.[1][2][3]

Applications

Typical uses include IC design verification, process monitoring, failure analysis, and reliability testing. The optional hot chuck system extends capability to temperature-dependent measurements from ambient to 300 °C.[1][2]

What do the numbers mean?

Power & electrical4

Max Number of Micro Positioners
10x DC/HV or 2x RF + 4x DC or 4x RF + 2x DC or 2x CAP + 4x DC[1]
Accurate?
Coax Chuck Operation Voltage
-200V to +200V DC[1]
Accurate?
Coax Chuck Max Voltage (Chuck to GND)
500 V DC[1]
Accurate?
Triax Chuck Isolation (Force to Guard @ 10V)
> 2 TΩ[1]
Accurate?

Wafer handling12

Chuck XY Stage Travel Range
205 mm x 205 mm (8.07 x 8.07 in)[1]
Accurate?
Chuck XY Travel Resolution (Standard)
14 μm Per Degree of Knob Rotation[1]
Accurate?
Chuck XY Travel Resolution (Fine)
1.5 μm Per Degree of Knob Rotation[1]
Accurate?
Chuck Z Stage Travel Range
2.5 mm (0.01 in)[1]
Accurate?
Chuck Z Stage Repeatability
± 1.0 μm[1]
Accurate?
Chuck Theta Stage Travel Range
± 11° (22°)[1]
Accurate?
Chuck Theta Stage Accuracy
< 1.0 μm (measured at the edge of the 200 mm chuck)[1]
Accurate?
Standard Wafer Chuck Diameter
203 mm[1]
Accurate?
Standard Wafer Chuck Surface Planarity
±6.5 μm[1]
Accurate?
Standard Wafer Chuck Rigidity
<3 μm / 10N at edge of the chuck[1]
Accurate?
Coax Chuck Isolation
> 150 GΩ[1]
Accurate?
Available Thermal Chuck Options
Standard Hot (25°C to 300°C), Hot/Triax (25°C to 200°C), Hot/3kV Triax (25°C to 200°C)[1]
Accurate?

Performance1

Contact Repeatability
< 1 μm (0.04 mils) by Manual Control[1]
Accurate?

Dimensions & facilities5

Probe Platen Dimensions
L = 580mm x W = 637mm x H = 12.7mm[1]
Accurate?
System Dimensions (Optional Table)
660 x 889 x 610 mm (26 x 35 x 24 in)[2]
Accurate?
System Weight (Optional Table)
109 kg (240 lbs)[2]
Accurate?
System Dimensions Including Table
863 x 1085 x 1370 mm (34 x 42.7 x 53.95 in)[2]
Accurate?
System Weight Including Table
385 kg (849 lbs)[2]
Accurate?

Configuration & options1

Probe Platen Material
Nickel Plated Steel (Aluminum optional)[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Max Number of Micro Positioners10x DC/HV or 2x RF + 4x DC or 4x RF + 2x DC or 2x CAP + 4x DC[1]
  • Coax Chuck Operation Voltage-200V to +200V DC[1]
  • Coax Chuck Max Voltage (Chuck to GND)500 V DC[1]
  • Triax Chuck Isolation (Force to Guard @ 10V)> 2 TΩ[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What wafer size does the CM 210 support?

The CM 210 supports full or partial wafer probing on wafers up to 200 mm. The standard chuck is 203 mm in diameter.[1][2]

What is the maximum temperature capability?

The CM 210 can be equipped with an optional hot chuck system that provides a temperature range from ambient up to 300 °C.[1][2]

Can the CM 210 be used for RF testing?

Yes, the CM 210 is designed for RF applications up to 110 GHz, with both 2-port and 4-port configurations available.[1][2]

What is the contact repeatability?

Contact repeatability is less than 1 μm by manual control.[1][2]

Not publicly documented

The following facts about the CM 210 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the CM 210 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the CM 210 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the CM 210 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the CM 210 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the CM 210 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]signatone.com — signatone.comsignatone.com
  2. [2]microworld.eu — microworld.eumicroworld.eu
  3. [3]Signatone CM-210 Checkmate 200mm high precision manual Probe Station | HMC Sales & Service | Semiconductor Equipment Distributor Singapore — hmcasia.comhmcasia.com
  4. [4]Equipment inventory listing
Was this page accurate?

Last updated Sep 30, 2026.

Compare with similar tools

View all →