Metrology & Inspection2"D-seriesKLA D600 family
Research Quality: 50% complete

The KLA Tencor D600 is a stylus surface profiler designed for advanced thin and thick film step height measurement. The D600 is compatible with 2", 4", 6", and 8" wafers. The D600 achieves a step-height repeatability of 5 angstroms.[1]

D600 — epfl.ch
Fig. 01D600epfl.ch[1]
  • Plate 01Tencor D-600 Thin Film profiler

    David InglisWatch on YouTube

Wafer size

2"

Performance

5A[1]

What it is

The KLA D600 is a stylus surface profiler manufactured by KLA Tencor (now KLA). The D600is designed for advanced thin and thick film step height measurement.[1]

How it works

General reference — not yet source-verified

Stylus surface profilers operate by dragging a diamond-tipped stylus across the sample surface. The stylus is in contact with the surface and its vertical displacement is measured as it traverses the step. The vertical movement is converted into an electrical signal via a transducer, producing a profilogram that shows the surface topography.

What can it run?

Process applications and technology nodes documented for this tool.

  • Thin film step height measurement
  • Thick film step height measurement

What do the numbers mean?

Wafer handling1

Wafer compatibility
2", 4", 6", and 8" wafers[1]
Accurate?

Performance3

Step-height repeatability
5A[1]
Accurate?
Step-Height Repeatability
5A (5 angstroms)[1]
Accurate?
Step-height repeatability
5 Å[1]
Accurate?

Dimensions & facilities3

Measurement purpose
Thin and thick film step height measurement[1]
Accurate?
Measurement application
Advanced thin- and thick-film step height measurement[1]
Accurate?
Measurement function
thin and thick film step height measurement[1]
Accurate?

Configuration & options10

Instrument type
Stylus surface profiler[1]
Accurate?
Field of view
3780 x 3120 um[1]
Accurate?
Digital zoom
x4[1]
Accurate?
Scan length range
55 mm with stitching option[1]
Accurate?
Vertical range
1 mm[1]
Accurate?
Force range
0.03 to 15 mg[1]
Accurate?
Digital Zoom
4x digital zoom[1]
Accurate?
Field of view
3780 x 3120 µm[1]
Accurate?
Documentation
D Series User Manual[1]
Accurate?
Type
stylus surface profiler[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What replaced it?

  • siblingKLA P-17— Listed in the same metrology equipment section.source[1]
  • siblingBruker Dektak XT— Listed in the same metrology equipment section.source[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What wafer sizes are compatible with the KLA D600?

The D600 is compatible with 2-inch, 4-inch, 6-inch, and 8-inch wafers.[1]

What is the vertical range of the D600?

The vertical range is 1 mm.[1]

What is the step-height repeatability of the D600?

The step-height repeatability is 5 Å.[1]

What is the maximum scan length of the D600?

The scan length range is 55 mm with the stitching option.[1]

What is the force range of the stylus on the D600?

The force range is 0.03 to 15 mg.[1]

Not publicly documented

The following facts about the D600 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the D600 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the D600 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the D600 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the D600 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the D600 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (1)Every fact above is drawn from these public sources
  1. [1]epfl.ch — epfl.chepfl.ch
Was this page accurate?

Last updated Oct 8, 2026.

Compare with similar tools

View all →