The Pfeiffer TPU 050 Vacuum is a turbomolecular vacuum pump. The Pfeiffer TPU 050 Vacuum uses a DN 63 CF inlet flange and a DN 16 KF outlet flange. The Pfeiffer TPU 050 Vacuum is specified with a nitrogen pumping speed of 50 l/s.[1][2][3]

TPU 050 Vacuum — Inventory photo
Fig. 01TPU 050 VacuumInventory photo[4]

What it is

The Pfeiffer TPU 050 is a turbomolecular drag pump with a CF flange inlet (DN 63 CF) and a KF outlet (DN 16 KF). The pump uses a wear-free permanent magnetic bearing on the high-vacuum side and an oil-lubricated ceramic bearing on the backing side.[1]

How it works

The Pfeiffer TPU 050 has a rated rotational speed of 90000 rpm. The pump employs a wear-free permanent magnetic bearing at the high vacuum side, which eliminates contact and wear, and an oil-lubricated ceramic bearing at the backing side. The pump is cooled by convection or water, with a water cooling requirement of 15 l/h.[1]

Applications

The Pfeiffer TPU 050 is used in a variety of applications including freeze drying, degassing, casting, dry vacuum smelting of super-pure metals, incandescent lamp manufacturing, electronic tube production, thin film deposition, space simulation, cryogenic research, electron microscopy, nuclear physics, plasma physics, high energy physics, and particle accelerators.[1]

What do the numbers mean?

Vacuum & pumping8

Type
Turbomolecular vacuum pump[3]
Accurate?
Proposed backing pump, minimum
1.5 m3/h[2]
Accurate?
Ultimate pressure, theoretical
10^-11 mbar[2]
Accurate?
Ultimate pressure 1
<1 x 10^-10 mbar[2]
Accurate?
Ultimate pressure 2
<1 x 10^-9 mbar[2]
Accurate?
Ultimate pressure 3
<5 x 10^-8 mbar[2]
Accurate?
Ultimate pressure
1 x 10^-11 mbar[1]
Accurate?
Bearing description
Permanent magnetic bearing at the high vacuum side and oil lubricated ceramic bearing at the backing side[1]
Accurate?

Dimensions & facilities3

Cooling water requirement
15 l/h[2]
Accurate?
Weight
2.5 kg[2]
Accurate?
Weight
6 kg[3]
Accurate?

Configuration & options25

Manufacturer
Pfeiffer[4]
Accurate?
Model
TPU 050[4]
Accurate?
Inlet flange
DN 63 CF[2]2 sources
Accurate?
Outlet flange
DN 16 KF[2]2 sources
Accurate?
Venting connection
DN 10 KF[2]
Accurate?
Volume flow rate for nitrogen
50 l/s[2]
Accurate?
Volume flow rate for helium
55 l/s[2]
Accurate?
Volume flow rate for hydrogen
50 l/s[2]
Accurate?
Compression ratio for nitrogen
8 x 10^8[2]
Accurate?
Compression ratio for helium
2.5 x 10^4[2]
Accurate?
Compression ratio for hydrogen
10^3[2]
Accurate?
Rated speed
90,000 U/min[2]
Accurate?
Run-up time
3 min[2]
Accurate?
Oil filling
1 cm3[2]
Accurate?
Cooling
Standard, up to an ambient temperature of 30 °C, convection/water[2]
Accurate?
Power input, heater
40 W[2]
Accurate?
Magnetic field, max.
7 mT[2]
Accurate?
Volume flow rate for nitrogen (N2)
50 l/s[3]
Accurate?
Volume flow rate for helium (He)
55 l/s[2]
Accurate?
Volume flow rate for hydrogen (H2)
50 l/s[3]2 sources
Accurate?
Compression ratio for nitrogen (N2)
8 x 10^8[3]
Accurate?
Compression ratio for helium (He)
2.5 x 10^4[2]
Accurate?
Compression ratio for hydrogen (H2)
10^3[2]
Accurate?
Cooling
Standard, up to an ambient temperature of 30 °C conv./water[2]
Accurate?
Cooling
Standard, convection / water; conversion kit for water/air[1]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
TPH 050——The TPH pumps have a KF or ISO-K flange, while the TPU pumps have a CF flange.ptbsales.com[3]
TMU——The TMU pumps are identical in design to the TMH pumps and differ only in intake flange.ptbsales.com[3]
TMH——The TMH pumps are identical in design to the TMU pumps and differ only in intake flange.ptbsales.com[3]
TMU 050——Identical in design to TPU models except for intake flange; the same letter signification applies to TMU and TMH pumps.ptbsales.com[3]
TMH 063——Identical in design to TPU models except for intake flange; the same letter signification applies to TMU and TMH pumps.ptbsales.com[3]
TMH 050——TMH and TMU models are described as identical in design and differing only in their intake flange.ajvs.com[2]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • TypeTurbomolecular vacuum pump[3]
  • Proposed backing pump, minimum1.5 m3/h[2]
  • Ultimate pressure, theoretical10^-11 mbar[2]
  • Ultimate pressure 1<1 x 10^-10 mbar[2]
  • Ultimate pressure 2<1 x 10^-9 mbar[2]
  • Ultimate pressure 3<5 x 10^-8 mbar[2]
  • Ultimate pressure1 x 10^-11 mbar[1]
  • Bearing descriptionPermanent magnetic bearing at the high vacuum side and oil lubricated ceramic bearing at the backing side[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the inlet flange type on the TPU 050?

The TPU 050 has a DN 63 CF inlet flange.[3][1]

What is the pumping speed for nitrogen?

The volume flow rate for nitrogen is 50 liters per second.[1][2]

What is the ultimate pressure achievable?

The ultimate pressure is 1 x 10^-10 mbar.[3][1]

What type of bearings does the TPU 050 use?

The pump uses a wear-free permanent magnetic bearing on the high-vacuum side and an oil-lubricated ceramic bearing on the backing side.[1][2]

Not publicly documented

The following facts about the TPU 050 Vacuum are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the TPU 050 Vacuum are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the TPU 050 Vacuum are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the TPU 050 Vacuum are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the TPU 050 Vacuum is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the TPU 050 Vacuum are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]ajvs.com — ajvs.comajvs.com
  2. [2]ajvs.com — ajvs.comajvs.com
  3. [3]ptbsales.com — ptbsales.comptbsales.com
  4. [4]Inventory photo
Was this page accurate?

Last updated Sep 29, 2026.

Compare with similar tools

View all →