Waferpedia

KLA

Surfscan SP 1 DLS

For Wafer Centering DeviceKLA Surfscan family
Research Quality: 40% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The KLA-Tencor Surfscan SP1 DLS is an unpatterned surface inspection system. The SP1 DLS detects, counts, and bins defects on polished wafers, epi wafers, and engineered substrates. The SP1 DLS offers 0.050 micrometer defect sensitivity on polished bare silicon and uses an argon ion laser at 488nm.[1][2]

Surfscan SP 1 DLS — Inventory photo
Fig. 01Surfscan SP 1 DLSInventory photo[3]

Wafer size

For Wafer Centering Device

Optics

Argon Ion Laser (488 nm)[1]

How it works

The Surfscan SP 1 DLS uses a 488 nm argon-ion laser as its illumination source. The laser beam is scanned across the wafer surface, and scattered light from defects is collected by photomultiplier tubes. The system achieves a defect sensitivity of 0.050 µm on polished bare silicon, as tested with polystyrene sphere (PSL) reference wafers.[1][5]

What do the numbers mean?

Wafer handling4

Wafer size
For Wafer Centering Device[3]
Accurate?
Wafer Size Support
200 mm and 300 mm[1]
Accurate?
Wafer Size
200/300mm[1]
Accurate?
Optional Handler
300mm Single FOUP/FIMS Handler[1]
Accurate?

Optics & imaging1

Laser Source
Argon Ion Laser (488 nm)[1]
Accurate?

Control & software1

Operator Interface
Yes[1]
Accurate?

Configuration & options13

Upgraded/New[3]
Accurate?
Y-Axis Linear Bearings (Only)[3]
Accurate?
Defect Sensitivity (Polished Bare Silicon)
0.050 µm[1]
Accurate?
Enhanced Rough Film Sensitivity
Yes[1]
Accurate?
Real Time Defect Classification (RTDC)
Yes[1]
Accurate?
Defect Map and Histogram with Zoom
Yes[1]
Accurate?
Map to Map
Yes[1]
Accurate?
Blower Unit
Yes[1]
Accurate?
OEM
KLA-Tencor[1]
Accurate?
Model
SP1 DLS[4]
Accurate?
Defect Sensitivity
0.050um on polished bare silicon[1]
Accurate?
Surface Type
Unpatterned[1]
Accurate?
Key Feature
Enhanced Rough Film Sensitivity[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What wafer sizes does the Surfscan SP1 DLS support?

The system is currently configured for 200 mm and 300 mm wafers, and it includes a 300 mm single FOUP/FIMS handler.[1]

What is the defect sensitivity of the Surfscan SP1 DLS?

The specified defect sensitivity is 0.050 µm on polished bare silicon.[1]

What type of laser does the Surfscan SP1 DLS use?

The system uses an argon ion laser with a wavelength of 488 nm.[1]

Does the Surfscan SP1 DLS have defect classification?

Yes, it includes Real Time Defect Classification (RTDC) capability.[1]

Not publicly documented

The following facts about the Surfscan SP 1 DLS are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Surfscan SP 1 DLS are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Surfscan SP 1 DLS are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Surfscan SP 1 DLS are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Surfscan SP 1 DLS are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Surfscan SP 1 DLS is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (6)Every fact above is drawn from these public sources
  1. [1]classoneequipment.com — classoneequipment.comclassoneequipment.com
  2. [2]KLA Tencor | Substrate — kla-tencor.com (May 21, 2009)web.archive.org
  3. [3]Inventory photo
  4. [4]Equipment inventory listing
  5. [5]KLA-Tencor Surfscan SP 1 DLS Unpatterened Surface Inspection 12 | SemiStar — semistarcorp.comsemistarcorp.com
  6. [6]KLA-Tencor | Products | Browse | Data Storage — tencor.com (Jul 27, 2003)web.archive.org
Was this page accurate?

Last updated Sep 22, 2026.

Compare with similar tools

View all →