Waferpedia

Agilent

N 9030 A

Agilent N 9030 A family
Research Quality: 40% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

AgilentN 9030 A
No photo available yet

Power

10 MHz[1]

Optics

1024 x 768 XGA, 213 mm (8.4 in) diagonal[2]

What it is

The Agilent N 9030 A PXA X-Series Signal Analyzer covers frequency ranges from 3 Hz up to 3.6, 8.4, 13.6, 26.5, 43, 44, or 50 GHz depending on the selected option.[1][2]

How it works

The N 9030 A uses a precision frequency reference with an aging rate of ± 1 × 10⁻⁷ per year and temperature stability of ± 1.5 × 10⁻⁸ over 20 to 30 °C.[1]

Applications

Signal analyzers are applied to the measurement of signal power, frequency, modulation quality, and distortion. The N 9030 A is suited for demanding applications in aerospace, defense, and commercial communications. The N 9030 A can measure channel power, adjacent channel power, occupied bandwidth, harmonic distortion, intermodulation, and burst power. The N 9030 A can perform spurious emission and spectrum emission mask testing.[1][2]

What do the numbers mean?

Power & electrical10

Frequency range (DC coupled)
3 Hz to 3.6 GHz (Option 503); 3 Hz to 8.4 GHz (Option 508); 3 Hz to 13.6 GHz (Option 513); 3 Hz to 26.5 GHz (Option 526); 3 Hz to 43 GHz (Option 543); 3 Hz to 44 GHz (Option 544); 3 Hz to 50 GHz (Option 550)[1]
Accurate?
Frequency range (AC coupled)
10 MHz to 3.6 GHz (Option 503); 10 MHz to 8.4 GHz (Option 508); 10 MHz to 13.6 GHz (Option 513); 10 MHz to 26.5 GHz (Option 526)[1]
Accurate?
Analysis bandwidth (standard)
10 MHz[1]
Accurate?
Analysis bandwidth (Option B25)
25 MHz[1]
Accurate?
Analysis bandwidth (Option B40)
40 MHz[1]
Accurate?
Analysis bandwidth (Option B85)
85 MHz[1]
Accurate?
Analysis bandwidth (Option B1X)
160 MHz[1]
Accurate?
Resolution bandwidth (RBW) range
1 Hz to 3 MHz (10% steps), 4, 5, 6, 8 MHz; with Option B85 and Option RBE: 10, 15, 20, 25, 30, 40, 50, 60, and 70 MHz; with Option B1X and Option RBE: 10, 15, 20, 25, 30, 40, 50, 60, 70, 80, 100, and 133 MHz[1]
Accurate?
Phase noise (CF = 1 GHz, specification, 10 kHz offset)
-130 dBc/Hz[2]
Accurate?
Displayed average noise level (DANL, preamp off, 10 MHz to 1.2 GHz)
-153 dBm (specification typical with sample or average detector, 0 dB input attenuation, 1 Hz RBW)[1]
Accurate?

Optics & imaging1

Display resolution
1024 x 768 XGA, 213 mm (8.4 in) diagonal[2]
Accurate?

Dimensions & facilities2

Weight (net, without options)
22 kg (48 lbs) nominal[2]
Accurate?
Dimensions (H x W x D)
177 mm x 426 mm x 556 mm (7.0 in x 16.8 in x 21.9 in)[2]
Accurate?

Configuration & options2

Operating temperature range
0 to 55 °C[2]
Accurate?
Power consumption (on, fully loaded)
450 W[2]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
N9030A-503——Frequency range 3 Hz to 3.6 GHztestequipment.center[2]
N9030A-508——Frequency range 3 Hz to 8.4 GHztestequipment.center[2]
N9030A-513——Frequency range 3 Hz to 13.6 GHztestequipment.center[2]
N9030A-526——Frequency range 3 Hz to 26.5 GHztestequipment.center[2]
N9030A-543——Frequency range 3 Hz to 43 GHz (preliminary specifications)testequipment.center[2]
N9030A-544——Frequency range 3 Hz to 44 GHz (preliminary specifications)testequipment.center[2]
N9030A-550——Frequency range 3 Hz to 50 GHz (preliminary specifications)testequipment.center[2]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Frequency range (DC coupled)3 Hz to 3.6 GHz (Option 503); 3 Hz to 8.4 GHz (Option 508); 3 Hz to 13.6 GHz (Option 513); 3 Hz to 26.5 GHz (Option 526); 3 Hz to 43 GHz (Option 543); 3 Hz to 44 GHz (Option 544); 3 Hz to 50 GHz (Option 550)[1]
  • Frequency range (AC coupled)10 MHz to 3.6 GHz (Option 503); 10 MHz to 8.4 GHz (Option 508); 10 MHz to 13.6 GHz (Option 513); 10 MHz to 26.5 GHz (Option 526)[1]
  • Analysis bandwidth (standard)10 MHz[1]
  • Analysis bandwidth (Option B25)25 MHz[1]
  • Analysis bandwidth (Option B40)40 MHz[1]
  • Analysis bandwidth (Option B85)85 MHz[1]
  • Analysis bandwidth (Option B1X)160 MHz[1]
  • Resolution bandwidth (RBW) range1 Hz to 3 MHz (10% steps), 4, 5, 6, 8 MHz; with Option B85 and Option RBE: 10, 15, 20, 25, 30, 40, 50, 60, and 70 MHz; with Option B1X and Option RBE: 10, 15, 20, 25, 30, 40, 50, 60, 70, 80, 100, and 133 MHz[1]
  • Phase noise (CF = 1 GHz, specification, 10 kHz offset)-130 dBc/Hz[2]
  • Displayed average noise level (DANL, preamp off, 10 MHz to 1.2 GHz)-153 dBm (specification typical with sample or average detector, 0 dB input attenuation, 1 Hz RBW)[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What analysis bandwidth options are available for the N 9030 A?

Standard analysis bandwidth is 10 MHz. Options include B25 (25 MHz), B40 (40 MHz), B85 (85 MHz), and B1X (160 MHz).[1]

Not publicly documented

The following facts about the N 9030 A are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the N 9030 A are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the N 9030 A are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the N 9030 A are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the N 9030 A is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the N 9030 A are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]keysight.com — keysight.comkeysight.com
  2. [2]testequipment.center — testequipment.centertestequipment.center
  3. [3]Equipment inventory listing
Was this page accurate?

Last updated Sep 24, 2026.

Compare with similar tools

View all →