Waferpedia

Agilent

8563 E Spectrum Analyzer

Produced –1999Agilent 85xx family
Research Quality: 30% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Agilent 8563E Spectrum Analyzer is a portable microwave spectrum analyzer. The Agilent 8563E Spectrum Analyzer has a standard frequency range of 9 kHz to 26.5 GHz. The Agilent 8563E Spectrum Analyzer offers fast digital resolution bandwidths of 1, 3, 10, 30, and 100 Hz.[1]

Agilent8563 E Spectrum Analyzer
No photo available yet

Produced

–1999

Power

9 kHz to 26.5 GHz[1]

What it is

The Agilent 8563E has a standard frequency range of 9 kHz to 26.5 GHz, preselected from 2.75 GHz to 26.5 GHz, with optional low-end frequency coverage to 30 Hz. The analyzer supports continuous 30 Hz to 26.5 GHz sweep. The instrument offers fast digital resolution bandwidths of 1, 3, 10, 30, and 100 Hz.[1]

How it works

The analyzer uses digitally implemented resolution bandwidths of 1, 3, 10, 30, and 100 Hz that sweep from 3 to 600 times faster than possible with comparable analog filters. A narrow 5:1 shape factor allows viewing of close-in, low-level signals easily. Digital bandwidths provide the spectrum analyzer with a full 100 dB onscreen calibrated display.[4]

The instrument includes a YTO (YIG-tuned oscillator) as its first local oscillator. The 8563E is presetected from 2.75 GHz to 26.5 GHz using a YIG-tuned filter/mixer (RYTHM) assembly. The 8563E has a LO distribution amplifier adjustment and a frequency response adjustment specific to this model.[2]

Applications

The 8563E is applied to adjacent-channel power (ACP) testing of burst carrier signals using digital modulation such as used in NADC-TDMA, GSM, DECT, CT2-CAI, PDC, and PHP systems. Adjacent channel power, channel power, carrier power, occupied bandwidth percentage, and time-gated measurements are standard. Measurement personalities for digital radio and phase noise measurements are available.[4][1]

Why won't it start?

Documented failure modes, common issues, and field considerations.

  • Intermittently shows overload message, even with no RF input

What do the numbers mean?

Power & electrical5

Intermittently shows overload message, even with no RF input[3]
Accurate?
Frequency range
9 kHz to 26.5 GHz[1]
Accurate?
Optional low-end frequency coverage
30 Hz[1]
Accurate?
Resolution bandwidths
1, 3, 10, 30, and 100 Hz[1]
Accurate?
Issue
Intermittently shows overload message, even with no RF input[3]
Accurate?

Configuration & options5

Model
8563E[3]
Accurate?
Manufacturer
Agilent[3]
Accurate?
Type
Spectrum Analyzer[3]
Accurate?
Tuning
Synthesized tuning[1]
Accurate?
Ruggedness
MIL-rugged[1]
Accurate?

Vintage & configurations

  1. 1999-10Production end[2]

    The service guide supplement is printed in October 1999.

Documented models & variants

DesignationGenerationVintageChangesSource
HP 8561E——The service guide states that the 8563E is one of the models covered alongside the HP 8561E.bee.mif.pg.gda.pl[2]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • ConfigurationIntermittently shows overload message, even with no RF input[3]
  • Frequency range9 kHz to 26.5 GHz[1]
  • Optional low-end frequency coverage30 Hz[1]
  • Resolution bandwidths1, 3, 10, 30, and 100 Hz[1]
  • IssueIntermittently shows overload message, even with no RF input[3]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the frequency range of the 8563E?

The standard frequency range is 9 kHz to 26.5 GHz, preselected from 2.75 GHz to 26.5 GHz, with optional low-end frequency coverage to 30 Hz. The analyzer supports continuous 30 Hz to 26.5 GHz sweep.[1]

What resolution bandwidths does the 8563E offer?

The analyzer offers fast digital resolution bandwidths of 1, 3, 10, 30, and 100 Hz, and additionally has 1 Hz resolution bandwidths.[4][1]

What standard measurements are available on the 8563E?

Adjacent channel power, channel power, carrier power, occupied bandwidth percentage, and time-gated measurements are standard.[1]

Is the 8563E ruggedized for field use?

Yes, the instrument is MIL-T-28800 rugged and built to withstand harsh environmental conditions.[1]

Not publicly documented

The following facts about the 8563 E Spectrum Analyzer are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • The control-system platform and OS era of the 8563 E Spectrum Analyzer are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • The process node or technology generation of the 8563 E Spectrum Analyzer is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 8563 E Spectrum Analyzer are on record.

    Answerable by: an OEM parts catalog or a service engineer

  • No publicly hosted manuals, SOPs, or datasheets for the 8563 E Spectrum Analyzer are on record.

    Answerable by: university cleanroom staff or an OEM application specialist

  • No description of the 8563 E Spectrum Analyzer is on record.

    Answerable by: an engineer who operated it or an OEM application specialist

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]testequipmentdepot.com — testequipmentdepot.comtestequipmentdepot.com
  2. [2]bee.mif.pg.gda.pl — bee.mif.pg.gda.plbee.mif.pg.gda.pl
  3. [3]inventory listing
  4. [4]Custom-Cal, Agilent HP / 8563E, 8564E, 8565E Repair and Calibration — custom-cal.comcustom-cal.com
Was this page accurate?

Last updated Oct 11, 2026.

Compare with similar tools