Precision OpticsAgilent 700 ICP-OES family
Research Quality: 40% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Agilent 700 ICP-OES is an optical emission spectrometer. The Agilent 700 ICP-OES is a full-spectrum direct-reading inductively coupled plasma optical emission spectrometer. The Agilent 700 ICP-OES has a wavelength range of 175–785 nm.[1]

Agilent700 ICP-OES
No photo available yet

Power

40.68 MHz[1]

Gas delivery

0–22.5 L/min (adjustable)[1]

Optics

Optical Emission Spectrometer[2]

What it is

The Agilent 700 ICP-OES is an inductively coupled plasma optical emission spectrometer.[2][1]

The Agilent 700 ICP-OES is a direct-reading optical emission instrument in the Agilent 700 Series.[1][3]

How it works

The Agilent 700 ICP-OES uses a full-spectrum direct-reading optical system with simultaneous capture across a continuous wavelength range from 175 to 785 nm.[1]

The Agilent 700 ICP-OES uses a high-resolution CCD detector and an echelle spectrograph architecture.[1]

Where it fits in the process flow

The Agilent 700 ICP-OES is used after sample preparation to quantify elemental composition in liquid analytical workflows.[1]

Applications

The Agilent 700 ICP-OES is used for high-throughput, multi-element trace and major elemental analysis.[1]

The Agilent 700 ICP-OES is applied in environmental, geological, metallurgical, pharmaceutical, and regulatory laboratories.[1]

What do the numbers mean?

Power & electrical1

RF generator frequency
40.68 MHz[1]
Accurate?

Gas & chemistry1

Plasma cooling gas flow
0–22.5 L/min (adjustable)[1]
Accurate?

Optics & imaging4

Instrument type
Optical Emission Spectrometer[2]
Accurate?
Instrument type
Full-spectrum direct-reading inductively coupled plasma optical emission spectrometer[1]
Accurate?
Wavelength range
175–785 nm (continuous, gap-free)[1]
Accurate?
Detector
High-resolution CCD with >1 million pixels, anti-blooming architecture[1]
Accurate?

Configuration & options7

Make
Agilent / Varian[2]
Accurate?
Model
700[2]
Accurate?
Focal length
0.4 m[1]
Accurate?
Echelle grating density
97.4 lines/mm[1]
Accurate?
Signal stability
≤1.0% RSD (4-hour measurement)[1]
Accurate?
Plasma output power
700–1700 W[1]
Accurate?
Origin
USA[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • RF generator frequency40.68 MHz[1]
  • Plasma cooling gas flow0–22.5 L/min (adjustable)[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What wavelength range does the Agilent 700 ICP-OES cover?

The Agilent 700 ICP-OES covers 175 to 785 nm continuously and without spectral gaps.[1]

What detector does the Agilent 700 ICP-OES use?

The Agilent 700 ICP-OES uses a high-resolution CCD detector with more than one million pixels and anti-blooming architecture.[1]

What RF operating frequency is given for the Agilent 700 ICP-OES?

The Agilent 700 ICP-OES is given with an RF generator frequency of 40.68 MHz.[1]

What plasma power range is given for the Agilent 700 ICP-OES?

The Agilent 700 ICP-OES is given with plasma output power from 700 to 1700 W.[1]

What major optical design details are given for the Agilent 700 ICP-OES?

The Agilent 700 ICP-OES is given with a 0.4 m focal length and a 97.4 lines per mm echelle grating.[1]

Not publicly documented

The following facts about the 700 ICP-OES are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 700 ICP-OES are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the 700 ICP-OES are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 700 ICP-OES are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 700 ICP-OES are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 700 ICP-OES is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]instrumenthive.com — instrumenthive.cominstrumenthive.com
  2. [2]Equipment inventory listing
  3. [3]Agilent 700 ICP-OES User Guide: Operation & Maintenance — studylib.netstudylib.net
Was this page accurate?

Last updated Sep 29, 2026.

Compare with similar tools

View all →