Waferpedia

Accretech

UF 300

Test & ProbeAccretech UF 300 family
Research Quality: 50% complete

The Accretech UF 300 is a wafer prober for test and probe applications. The UF 300 handles 8-inch and 12-inch wafers. The UF 300 includes automatic alignment and a loader.[1][2]

UF 300 — Inventory photo
Fig. 01UF 300Inventory photo[1]
  • Plate 01UF300 TSK/ACCRETECH Wafer Prober

    Gustavo OrtegaWatch on YouTube

What it is

The Accretech UF 300 is a test and probe wafer prober.[2][1]

How it works

The UF 300 includes automatic alignment for the needle and wafer, needle height setting, and wafer loading support.[1][2]

The UF 300 uses GPIB interface control and includes an operator terminal and keyboard.[1][2]

Where it fits in the process flow

The UF 300 supports wafer-level handling with a loader, an inspection tray, and automatic alignment functions for probe placement.[1][2]

Applications

General reference — not yet source-verified

The UF 300 is used for wafer-level electrical probing of semiconductor devices.

What do the numbers mean?

Wafer handling8

Includes Loader[1]
Accurate?
12" Chuck[1]
Accurate?
Chuck Controller
Ambient to 125°C[1]
Accurate?
Auto Alignment
Yes, Needle & Wafer[1]
Accurate?
Wafer Loader
Foup & Inspection Tray[1]
Accurate?
Wafer sizes
8 inch, 12 inch[1]
Accurate?
Includes loader
Yes[1]
Accurate?
Chuck
12 inch chuck[1]
Accurate?

Performance2

XY Position Accuracy
Yes[1]
Accurate?
Needle Alignment
Yes[1]
Accurate?

Control & software1

Interface
GPIB[1]
Accurate?

Dimensions & facilities1

Auto Needle Height Setting
Yes[1]
Accurate?

Configuration & options18

OCR
Yes[1]
Accurate?
Cleaning Pad
Yes / Ceramic[1]
Accurate?
Color LCR Display[1]
Accurate?
GPIB
Yes[1]
Accurate?
Operator Terminal & Keyboard[1]
Accurate?
Power Cord for Prober[1]
Accurate?
Floppy Disk with Accretech Configuration Files[1]
Accurate?
Backup of Configuration Files on the Internal Hard Drive Inside the Prober[1]
Accurate?
Manufacturer
Accretech / TSK[1]
Accurate?
Model
UF 300[1]
Accurate?
Category
Test & Probe[2]
Accurate?
Color LCR display
Yes[1]
Accurate?
Operator terminal & keyboard
Included[1]
Accurate?
Power cord for prober
Included[1]
Accurate?
Floppy disk with configuration files
Included[1]
Accurate?
Backup of configuration files
On internal hard drive inside the prober[1]
Accurate?
Power Cord
Included[1]
Accurate?
Backup of Configuration Files on Internal Hard Drive
Included[1]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
UF 300 A Automatic Wafer—2001Described as a 2001 vintage automatic wafer prober for 8-inch wafers with single phase power, 208V, automatic probe to pad alignment, automatic needle height alignment, new E2 camera update, nickel chuck, gold plated chuck, fully automatic operation, probe card change, keyboard and joystick, 3.5-inch floppy disk / 3.5-inch hard disk, internal printer, GPIB I/F, RS232 I/F, Ethernet I/F, Cognex board type 8200, probe mark inspection, multi-die probing up to 256 DUTs, multi function cleaning pad, and soak time option.waferpedia.com[5]
Interested in this tool?
Need help with this tool?Embed spec card

What replaced it?

Alternatives

Tools documented as functional equivalents — same process step and wafer size, from a different manufacturer. Each equivalence cites its source.

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

Does the UF 300 include automatic alignment?

The UF 300 includes automatic alignment for the needle and wafer.[2][5]

What interface does the UF 300 use?

The UF 300 uses GPIB interface control.[2]

Does the UF 300 include a wafer loader?

The UF 300 includes wafer loading support and a wafer loader.[2][1]

Not publicly documented

The following facts about the UF 300 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the UF 300 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the UF 300 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the UF 300 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the UF 300 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the UF 300 are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (11)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]waferpedia.com — waferpedia.comwaferpedia.com
  3. [3]Inventory photo
  4. [4]Inventory photo
  5. [5]waferpedia.com — waferpedia.comwaferpedia.com
  6. [6]web.archive.orgweb.archive.org
  7. [7]web.archive.orgweb.archive.org
  8. [8]sec.govsec.gov
  9. [9]Equipment inventory listing
  10. [10]Equipment inventory listing
  11. [11]waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 1, 2026.

Compare with similar tools

View all →