Waferpedia

Comparison ledger

PRS900versus1000FP

Oxford Instruments PRS900, YES 1000FP, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
PRS900Oxford Instruments
OEMOxford InstrumentsYES
CategoryWet Processing / CleanWet Processing / Clean
Wafer size6"—
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyOxford Instruments PRS900YES 1000FP
Specifications
Tool typeplasma stripper; barrel reactor[1]—
Processdedicated to dry resist stripping[1]—
Etching characterpurely chemical and isotropic[1]—
Plasma sourceoxygen plasma (RF capacitive or micro-wave)[1]—
Automationcompletely computer driven[1]—
Carrierquartz samples carrier[1]—
Carrier wafer size4 or 6 inches[1]—
Batch capacityup to 25 wafers[1]—
Resistance etch rate used at CMi0.035 um/min[1]—
TypeBarrel reactor[1]—
Chamber configurationBarrel acts as Faraday cage, RF waves do not enter chamber; plasma UV radiations not filtered[1]—
Maximum wafers per batch25[1]—
Wafer carrierQuartz samples carrier (4 or 6 inches)[1]—
Mean resist etch rate0.035 µm/min for PR (for 5, 30, or 60 min recipes)[1]—
Computer controlCompletely computer driven[1]—
Etch typePurely chemical, isotropic[1]—
Wafer carrier sizes4 or 6 inches[1]—
Mean PR etch rate0.035 µm/min[1]—
Standard process recipesPR Ox5 (5 min), PR Ox30 (30 min), PR Ox60 (60 min)[1]—
Reactor typeBarrel reactor[1]—
Process typeDry resist stripping; etching processes are purely chemical and isotropic[1]—
Reactor shieldingThe barrel acts as a Faraday cage so RF waves do not enter the treatment chamber[1]—
UV behaviorPlasma UV radiations are not filtered and thermally activate the oxidation[1]—
ControlCompletely computer driven; the only manual handling is the loading/unloading step of the quartz samples carrier[1]—
Recipe PR Ox5 (5 min)Mean etch rate 0.035 µm/min; stripping of PR residuals after photolithography[1]—
Recipe PR Ox30 (30 min)Mean etch rate 0.035 µm/min; stripping of ~1 µm of PR[1]—
Recipe PR Ox60 (60 min)Mean etch rate 0.035 µm/min; stripping of ~2 µm of PR[1]—
Forbidden materialsCu, Ag, Au, Cr — equipment must remain microelectronic compatible[1]—
Primary usedry resist stripping[1]—
Carrier typequartz samples carrier[1]—
Carrier capacityup to 25 wafers[1]—
System type—Plasma cleaning system[2]
Line—R-Series Plasma Cleaning Systems (Glen Technologies)[2]
Model—Glen/YES 1000FP[2]
Designed use—Designed to accept a range of shelf sizes[2]
Application focus—Changing needs of the flat panel industry[2]

Plan your fab

Building a Wet Processing / Clean process? Get a complete equipment list.

Open the fab equipment planner →
Sources (2)Every fact above is drawn from these public sources