Comparison ledger
Applied Materials 0020 34833 Part, Keysight 34465 A, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | 0020 34833 PartApplied Materials | 34465 AKeysight |
|---|---|---|
| OEM | Applied Materials | Keysight |
| Category | Lab & Support Equipment | Lab & Support Equipment |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | — |
| Lifecycle | — | — |
| Lifecycle milestones | — | — |
| Control system | — | — |
| Generation | — | — |
| Family | Applied Materials 0020 34833 Part | Keysight 34465 A |
| Cited variants | — | |
| Specifications | ||
| Configuration | Block Cont Mount H / V Interlock[2] | — |
| Digits of resolution | — | 6½[1] |
| Basic DC voltage accuracy (1 year, TCAL ±5°C) | — | 0.0030% of reading + 0.0004% of range (10 V range)[1] |
| Max reading rate (standard digitizing) | — | 5,000 readings/s[1] |
| Max reading rate (optional digitizing) | — | 50,000 readings/s[1] |
| Memory (standard) | — | 50,000 readings[1] |
| Memory (optional) | — | 2 million readings[1] |
| DC voltage ranges | — | 100 mV to 1000 V[1] |
| AC voltage ranges (RMS) | — | 100 mV to 750 V[1] |
| DC current ranges | — | 1 μA to 10 A[1] |
| AC current ranges (RMS) | — | 100 μA to 10 A[1] |
| 2- and 4-wire resistance ranges | — | 100 Ω to 1000 MΩ[1] |
| Capacitance ranges | — | 1.0 nF to 100.0 μF[1] |
| Frequency range | — | 3 Hz to 300 kHz[1] |
| Temperature measurement | — | RTD/PT100, thermistor, thermocouples (K,J,T,E,N,R)[1] |
| Display | — | Color graphical, 4.3-inch, dual line display[1] |
| Interface - USB | — | Yes[1] |
| Interface - LAN/LXI Core | — | Optional[1] |
| Interface - GPIB | — | Optional[1] |
| Basic DCV accuracy | — | 30 ppm[1] |
| Max reading rate (standard) | — | 5,000 rdgs/s[1] |
| Max reading rate (with DIG option) | — | 50,000 rdgs/s[1] |
| Volatile reading memory (standard) | — | 50,000 rdgs[1] |
| Volatile reading memory (with MEM option) | — | 2,000,000 rdgs[1] |
| AC voltage ranges | — | 100 mV to 750 V[1] |
| AC current ranges | — | 100 μA to 10 A[1] |
| Resistance ranges | — | 100 Ω to 1,000 MΩ[1] |
| Temperature measurement types | — | RTD/PT100, thermistor, thermocouples[1] |
| Weight (34461/65/70A) | — | 3.76 kg (8.3 lb)[1] |
| Bench dimensions (W x H x D) | — | 261.2 mm x 103.8 mm x 303.2 mm[1] |
| Standard interfaces | — | USB, LAN/LXI core, optional GPIB[1] |
| Series | — | Truevolt[3] |
| DC Voltage Accuracy (1 year, 10 V range) | — | 0.0030% of reading + 0.0004% of range[1] |
| Maximum Reading Rate (DC, standard) | — | 5,000 readings/s[1] |
| Maximum Reading Rate (DC, with option) | — | 50,000 readings/s[1] |
| Memory (with option) | — | 2 million readings[1] |
| Measurement Functions | — | DCV, ACV, DCI, ACI, 2-wire/4-wire resistance, capacitance, frequency, period, temperature (RTD, thermistor, thermocouple), diode, continuity[1] |
| Basic DCV Accuracy (1 year, 10 V range) | — | 30 ppm[1] |
| Rear Panel I/O Interfaces (standard) | — | LAN/LXI, USB, external trigger[1] |
| Max reading rate | — | 5,000 rdgs/s (standard), 50,000 rdgs/s optional[1] |
| Memory | — | 50,000 readings standard, 2 million optional[1] |
| Weight | — | 3.76 kg (8.3 lb)[1] |
| Interfaces | — | LAN/LXI, USB, optional GPIB[1] |
| Autocalibration | — | ACAL capable[1] |