Comparison ledger
Agilent 8566 B Spectrum Analyzer, Applied Materials 0010-03254 E Chuck, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | 8566 B Spectrum AnalyzerAgilent | 0010-03254 E ChuckApplied Materials |
|---|---|---|
| OEM | Agilent | Applied Materials |
| Category | — | — |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | — |
| Lifecycle | — | — |
| Lifecycle milestones | — | — |
| Control system | — | — |
| Generation | — | — |
| Family | Agilent 85xx | — |
| Cited variants | — | |
| Specifications | ||
| Configuration | with Display[2] | — |
| Instrument type | Spectrum analyzer[2] | — |
| Frequency range | 100 Hz to 22 GHz[1] | — |
| Preselected tuning range | 2 to 22 GHz[3] | — |
| Measurement range | -135 dBm to +30 dBm[1] | — |
| Input | dc-coupled input[1] | — |
| Instrument composition | 85662A Display Section and 85660B RF Section[3] | — |
| Support status | Agilent no longer sells or supports this product[4] | — |
| Power requirements | 50 to 60 Hz; 100, 200, 120, 220, or 240 V (+5%, -10%); approximately 650 VA (40 VA in standby)[1] | — |
| Display technology | Cathode ray tube with post deflection accelerator, aluminized P31 phosphor, electrostatic focus and deflection[1] | — |
| Model | 8566B Spectrum Analyzer[2] | — |
| OEM | Agilent[2] | — |
| Low-frequency band | 100 Hz to 2.5 GHz[3] | — |
| Microwave band | 2 to 22 GHz[3] | — |
| Instrument sections | 85662A Display Section and 85660B RF Section[3] | — |
| Frequency span | 0 Hz, 100 Hz to 22 GHz over 10 division CRT horizontal axis; variable in approximately 1% increments[1] | — |
| Resolution bandwidth | 10 Hz to 3 MHz in a 1, 3, 10 sequence[1] | — |
| Amplitude measurement range | +30 to -135 dBm[1] | — |
| Reference level range, log | +30.0 to -99.9 dBm or equivalent in dBmV, dBμV, volts; expandable to +60.0 dBm to -119.9 dBm[1] | — |
| RF input | 100 Hz to 22 GHz, precision type-N female connector, dc-coupled[1] | — |
| Maximum input level, continuous power | +30 dBm from 50 ohm source[1] | — |
| Input attenuator | 0 to 70 dB in 10 dB steps[1] | — |
| Display outputs | X, Y, and Z outputs for auxiliary CRT displays; X and Y 1 V for full deflection; Z 0 to 1 V intensity modulation; BLANK TTL level > 2.4 V[1] | — |
| Recorder outputs | Horizontal sweep output, video output, and penlift output for X-Y recorders[1] | — |
| Frequency reference output | 10.000 MHz, 0 dBm, 50 ohm output impedance[1] | — |
| Sweep and tune output | -1 V/GHz of tuned frequency ±(2% + 10 mV), 10 kohm impedance[1] | — |
| Remote operation | GP-IB; all analyzer control settings except video trigger level, focus, align, intensity, freq zero, amptd cal, and line power are remotely programmable[1] | — |