Waferpedia

Comparison ledger

-407B-2-S-CE-S293 Robotversus34401 A Multimeter

ABM -407B-2-S-CE-S293 Robot, Agilent 34401 A Multimeter, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
OEMABMAgilent
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyABM -407B-2-S-CE-S293 RobotAgilent 34401 A Multimeter
Cited variants—
  • Agilent/ HP 34401A Multimeter 6.5 Digit[1]
  • AGILENT/HP 34401A 6 1/2 DIGIT MULTIMETER[2]
Specifications
ModelABM-407B-2-S-CE-S293[3]—
DescriptionROBOT[3]—
Refurbished RTP RTAAG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[3]—
KLA-Tencor Spare Parts and ServiceRS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[3]—
Refurbished Isotropic Plasma EtcherMatrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[3]—
Refurbished PECVD, ALD EquipmentCambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[3]—
Refurbished Mask AlignerCanon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[3]—
Refurbished BondingSUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[3]—
Refurbished Wafer ProberElectroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[3]—
~ Line—45 - 440 Hz, 25va Max[4]
Voltage Selector Positions—100 / 120 / 220 / 240 V~[4]
Fuse—250v, 250ma[4]
Voltage—100 V ~ 120 V[5]
Measurement resolution—6.5 digits[1]
DC voltage accuracy—0.0015%[1]
AC voltage accuracy—0.06%[1]
AC measurement type—True RMS[1]
Maximum reading rate—1000 readings per second in ASCII format[1]
Interfaces—RS-232 and GPIB[1]
DC voltage range—100 mV to 1000 V[2]
DC current range—100 µA to 10 A[2]
AC voltage range—100 mV to 750 V[2]
AC current range—100 µA to 10 A[2]
Resistance range—100 Ω to 10 MΩ[2]
Frequency range—1 Hz to 300 kHz[2]
Diode testing range—forward voltage 2 V, current 1 mA[2]
DC voltage accuracy (alternate)—0.0035% + 5 µV[2]
DC current accuracy—0.02% + 400 nA[2]
AC voltage accuracy (alternate)—0.06% + 20 µV[2]
AC current accuracy—0.2% + 2 µA[2]
Resistance accuracy—0.05% + 20 mΩ[2]
Frequency accuracy—0.01% + 5 mHz[2]
Display—5.5-digit LCD with refresh rate 5 readings/s[2]
Power supply—100-240 V AC, 50/60 Hz[2]
Line frequency (mains)—45 - 440 Hz, 25 VA max[4]
Fuse rating—250 V, 250 mA[4]
Resolution—6.5 digits[1]
DC measurement accuracy—0.0015%[1]
AC measurement accuracy—0.06%[1]
True RMS AC measurement—Yes[1]
Max reading rate—1000 readings per second (ASCII over GPIB)[1]
Functions—More than a dozen functions accessible with one or two key presses[1]
Diode testing—Forward voltage range 2 V, current range 1 mA[2]
Power supply (Micro Precision)—100-240 V AC, 50/60 Hz[2]
Measurement capabilities—DC voltage, DC current, AC voltage, AC current, resistance, frequency, and diode testing[2]
Line frequency range—45-440 Hz[4]
Max power—25 VA[4]
Sources (5)Every fact above is drawn from these public sources
  1. [1]calright.comcalright.com
  2. [2]microprecision.commicroprecision.com
  3. [3]dealer listingsemistarcorp.com
  4. [4]inventory listing