Waferpedia

Comparison ledger

.498 PSL WaferversusSurfscan 6220

KLA .498 PSL Wafer, KLA Surfscan 6220, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
OEMKLAKLA
CategoryMetrology & InspectionMetrology & Inspection
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyKLA .498 PSL WaferKLA Surfscan 6220
Specifications
ConfigurationNIST Traceable[1]Single Phase[2]
NIST traceabilityYes[1]—
Frequency—60 Hz[2]
Voltage—208 V[2]
Equipment type—Bare wafer surface defect inspection system / Particle inspection system[3]
Substrate sizes (inch)—2", 3", 4", 6", 8"[3]
Substrate sizes (metric)—100 mm, 125 mm, 150 mm, 200 mm (round or rectangular)[4]
Wafer thickness—SEMI Standard Wafer Thickness[3]
Material compatibility—Any opaque, polished surface which scatters less than 5 percent of incident light[3]
Defect sensitivity (most surfaces)—Better than 0.20 µm @ 95% capture rate[4]
Defect sensitivity (polished surfaces)—Better than 0.10 µm @ 95% capture rate[4]
Defect sensitivity (bare silicon)—0.12 µm[4]
Defect sensitivity (PSL sphere equivalent)—0.09 µm diameter @ >80% capture rate (0.112 µm @ 90%)[3]
Count repeatability—Error less than 0.5% at 1 standard deviation (mean count >500, 0.364 mm dia. latex spheres)[3]
Count repeatability (alternate)—Less than 1.0% at 1 standard deviation (mean count >500, 0.204 µm diameter latex spheres on bare silicon)[4]
Count accuracy—Better than 99% (verified with VLSI Standards’ Relative Standard)[3]
Throughput—100 wph (200 mm) at 0.12 µm[3]
Contamination—Less than 0.005 particles/cm² >0.15 µm diameter per single pass[3]
Contamination (alternate)—Less than 0.005 particles/cm >0.15 µm[4]
Haze sensitivity—0.02 ppm[4]
Illumination source—30 mW Argon-Ion laser, 488 nm wavelength[3]
Spatial resolution—50 µm[4]
Signal integration—2D signal integration[4]
Wafer handling—Single puck wafer handling from two cassettes (one sender/receiver, one receiver); non-contaminating robotic handler[3]
Wafer handling (alternate)—Non-contaminating robotic handler; random access sender/receiver unit[4]
Operator interface—Mouse and/or dedicated user keypad[3]
Electrical requirements—Single phase, 60 Hz, 17 A, 208 V[2]
OEM—KLA[2]
Model—Surfscan 6220[2]
Product type—Wafer Particle Detection System[5]
Wafer sizes—2", 3", 4", 6", and 8" wafers[3]
Substrate sizes—100, 125, 150, and 200 mm (round or rectangular substrates)[4]
Sensitivity—0.09 micrometer diameter PSL sphere equivalent with greater than 80 percent capture rate[3]
Repeatability—Count repeatability error less than 0.5 percent at 1 standard deviation[3]
Accuracy—Count accuracy better than 99 percent[3]
Cassette handling—Single puck wafer handling from two cassettes (one sender/receiver, one receiver)[3]
Vintage—1996[2]

Plan your fab

Building a Metrology & Inspection process? Get a complete equipment list.

Open the fab equipment planner →
Sources (6)Every fact above is drawn from these public sources
  1. [1]inventory listing
  2. [2]inventory listing
  3. [3]classoneequipment.comclassoneequipment.com
  4. [4]semistarcorp.comsemistarcorp.com
  5. [5]fabsurplus.comfabsurplus.com
  6. [6]yorkscientific.comyorkscientific.com