Waferpedia

Comparison ledger

1007versus370 A Programmable Curve Tracer

KLA 1007, Tektronix 370 A Programmable Curve Tracer, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
1007KLA
OEMKLATektronix
CategoryTest & ProbeTest & Probe
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyKLA 1007Tektronix 370 A Programmable Curve Tracer
Specifications
ManufacturerKLA[1]—
Model1007[1]—
DescriptionWafer Prober[1]—
Wafer size150 mm[1]—
Convertible to 8 inch wafer sizeYes[1]—
Vintage01.06.1995[1]—
MakeKLA[2]—
Equipment typeProber[2]—
Configuration—Built onto a cart[3]
Collector Supply Modes—AC, ±DC, ±Leakage, ±Rectified Sine[4]
Maximum Peak Current (16 V range)—10 A (20 A pulsed)[4]
Maximum Peak Current (80 V range)—2 A (4 A pulsed)[4]
Maximum Peak Current (400 V range)—0.4 A (0.8 A pulsed)[4]
Maximum Peak Current (2000 V range)—0.05 A (0.1 A pulsed)[4]
Step Generator Modes—Stair step: DC, 80 µs pulse, 300 µs pulse[4]
Step Range (Current)—50 nA to 200 mA in 1-2-5 sequence[4]
Step Range (Voltage)—50 mV to 2 V in 1-2-5 sequence[4]
Offset—Up to ±10X step amplitude[4]
Number of Steps—0 to 10[4]
Collector Current Measurement Range—100 nA/div (1 nA resolution) to 2 A/div[4]
Collector Current Accuracy—1.5% of cursor readout +0.05 div of setting (with dot cursor)[4]
Emitter Current Measurement Range—1 nA/div (10 pA resolution) to 2 mA/div[4]
Emitter Current Accuracy—1.5% of cursor readout +0.05 div of setting +1 nA[4]
Measurement Resolution—1 nA current resolution, 2 mV voltage resolution[4]
Safety Certifications—UL1244, CSA231, HD401 S1 K475[4]
Interface—IEEE Standard 488.1-1987, RS-232-C, Tektronix Standard Codes and Formats[4]
Storage—3.5-inch MS DOS-compatible disk, nonvolatile memory[4]
Test Fixture Adapters—A1001-A1005 (Kelvin sensing), 3-Pin adapters (non-Kelvin), A1023/A1024 surface mount adapters[4]
Accessories—K475 Instrument Cart[4]
Display Features—Waveform Comparison, Envelope Display, Waveform Averaging, Dot Cursor[4]
EMC Compliance—Directive 89/336/EEC, EN 55011 Class B (radiated and conducted), EN 60555-2[5]
Installation Category—CAT II (as defined in IEC 1010-1, Annex J)[5]