Comparison ledger
Applied Materials 0010-21246 Part, Keysight E 5250 A Low Leakage Switch Mainframe, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | 0010-21246 PartApplied Materials | |
|---|---|---|
| OEM | Applied Materials | Keysight |
| Category | — | — |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | — |
| Lifecycle | — | — |
| Lifecycle milestones | — | — |
| Control system | — | — |
| Generation | — | — |
| Family | — | Keysight E 5250 A Low Leakage Switch Mainframe |
| Specifications | ||
| Power requirements | — | 100/120/220/240 V ± 10%, 47 Hz to 63 Hz[1] |
| Maximum VA | — | 100 VA[1] |
| Number of slots | — | 4 slots for 30-mm height switch cards[1] |
| Size (mainframe) | — | 230 mm H x 430 mm W x 600 mm D[1] |
| Size (E5252A card) | — | 30 mm H x 395 mm W x 424 mm D[1] |
| Size (E5255A card) | — | 30 mm H x 395 mm W x 424 mm D[1] |
| Weight (mainframe) | — | 11.2 kg[1] |
| Weight (E5252A) | — | 2.0 kg[1] |
| Weight (E5255A) | — | 2.1 kg[1] |
| Operating temperature range | — | 5°C to 40°C[1] |
| Storage temperature range | — | -40°C to 70°C[1] |
| Operating humidity range | — | 5% to 80% (no condensation)[1] |
| Storage humidity range | — | 5% to 90% RH at 65°C[1] |
| Altitude (operating) | — | 0 to 2000 m (6500 ft)[1] |
| Altitude (storage) | — | 0 to 15,240 m (50,000 ft)[1] |
| No. of ports (with E5252A matrix) | — | Low leakage I-V Port: 2, General I-V Port: 4, C-V Port: 2, HF Port: 2, Output Channels: 12[1] |
| No. of ports (with E5255A multiplexer) | — | Low leakage I-V Port: 3, Bias Port: 3, Output Channels: 24 (8 x 3)[1] |
| Max current rating (E5252A) | — | 1.0 A[1] |
| Max voltage rating (E5252A) - channel to ground | — | 200 V[1] |
| Max voltage rating (E5252A) - channel to channel | — | 300 V[1] |
| Close channel residual R (E5252A) - Low Leakage I-V Port | — | 0.6 Ω[1] |
| Close channel residual R (E5252A) - General I-V Port | — | 1.0 Ω[1] |
| Close channel residual R (E5252A) - C-V, HF Port | — | 1.0 Ω[1] |
| Channel isolation R (E5252A) - Low Leakage I-V Port (Condition A) | — | 1e13 Ω[1] |
| Channel isolation R (E5252A) - General I-V Port (Condition A) | — | 1e12 Ω[1] |
| Channel isolation R (E5252A) - C-V, HF Port (Condition A) | — | 1e9 Ω[1] |
| Typical offset current (E5252A) - Low Leakage I-V Port | — | < 0.1 pA[1] |
| Typical offset current (E5252A) - General I-V Port | — | < 1000 pA[1] |
| Typical channel crosstalk capacitance (E5252A) | — | < 0.3 pF/ch[1] |
| Typical offset voltage (EMF) at 5 min (E5252A) - Low Leakage I-V Port | — | < 80 μV[1] |
| Typical guard capacitance (E5252A) - Low Leakage I-V Port | — | < 145 pF[1] |
| Bandwidth (-3 dB) (C-V, HF Port) | — | < 10 MHz[1] |
| Relay contact life (dry switching mode) | — | > 10^8 times[1] |
| Settling time (Low Leakage I-V Port) | — | < 3.5 sec / 0.4 pA[1] |