Comparison ledger
Agilent 7700 Series ICP-MS, OGP 0020 Contour Projector, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | 7700 Series ICP-MSAgilent | |
|---|---|---|
| OEM | Agilent | OGP |
| Category | Precision Optics | Precision Optics |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | — |
| Lifecycle | — | — |
| Lifecycle milestones | 2026 OEM support ended | — |
| Control system | — | — |
| Generation | — | — |
| Family | Agilent 7700 | OGP (Optical Gaging Products) 0020 Contour Projector |
| Cited variants | — | |
| Specifications | ||
| Configuration | Agilent 7700 Series ICP/MS[3] | 50-60 Cycle[5] |
| Mass Analyzer | Quadrupole[1] | — |
| Mass Range | 2-260 amu[4] | — |
| Scan Speed | 100 milliseconds (for full mass range)[4] | — |
| Detector | Electron Multiplier (pulse and analog modes)[4] | — |
| Sensitivity (7700x) Li (7) | 50 Mcps/ppm[1] | — |
| Sensitivity (7700x) Y (89) | 160 Mcps/ppm[1] | — |
| Sensitivity (7700x) Tl (205) | 80 Mcps/ppm[1] | — |
| Sensitivity (7700s) Li (7) | 50 Mcps/ppm[1] | — |
| Sensitivity (7700s) Y (89) | 240 Mcps/ppm[1] | — |
| Sensitivity (7700s) Tl (205) | 120 Mcps/ppm[1] | — |
| Sensitivity (7700e) Li (7) | 20 Mcps/ppm[2] | — |
| Sensitivity (7700e) Y (89) | 80 Mcps/ppm[2] | — |
| Sensitivity (7700e) Tl (205) | 40 Mcps/ppm[2] | — |
| Background on-mass (No gas, 9 amu) - 7700x | <2 cps[1] | — |
| Background on-mass (No gas, 9 amu) - 7700s | <3 cps[1] | — |
| Background on-mass (He cell gas, 9 amu) - 7700x | <0.5 cps[1] | — |
| Background on-mass (He cell gas, 9 amu) - 7700s | <0.5 cps[1] | — |
| Oxide ratio (CeO/Ce) - 7700x | <1.5%[1] | — |
| Oxide ratio (CeO/Ce) - 7700s | <3%[1] | — |
| Doubly-charged ratio (Ce2+/Ce) - 7700x | <3%[1] | — |
| Doubly-charged ratio (Ce2+/Ce) - 7700s | <6%[1] | — |
| Short-term stability (20 min, %RSD) | <3% (7700x, 7700s)[1] | — |
| Long-term stability (2 hours, %RSD) | <4% (7700x, 7700s)[1] | — |
| Power Supply | Single Phase, 200-240V, 50/60Hz, 30A[1] | — |
| Dimensions (mainframe, W x D x H) | 730 x 620 x 595 mm[1] | — |
| Weight (mainframe) | 115 kg[1] | — |
| Argon Gas Supply (minimum purity) | 99.99%[1] | — |
| Argon Gas Supply (maximum flow rate) | 20 L/min[1] | — |
| Argon Gas Supply (supply pressure) | 500-700 kPa[1] | — |
| Sensitivity (Y 89) | 160 Mcps/ppm (7700x) / 240 Mcps/ppm (7700s)[1] | — |
| Sensitivity (Tl 205) | 80 Mcps/ppm (7700x) / 120 Mcps/ppm (7700s)[1] | — |
| Oxide ratio (CeO/Ce) | <1.5% (7700x) / <3% (7700s)[1] | — |
| Mainframe dimensions (W x D x H) | 730 mm x 620 mm x 595 mm[1] | — |
| Mainframe weight | 115 kg[1] | — |
| RF power range | 500 W to 1600 W, in steps of 10 W[2] | — |
| Sampling depth | 3 to 28 mm[1] | — |
| Voltage | — | 115 V[5] |
Plan your fab